Scheduled waste - sampling technical guide - Part 2: Description of media and device selection guide
MS 2070-2:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard provides guidance on selecting appropriate sampling tools and devices, conducting sampling activities, and using sample homogenisation, splitting, and subsampling techniques.

RM 15.00

Document will be sent via email



 Add To Cart

PRACTICE FOR DETERMINATION OF VOLATILES IN POLYMERS BY STATIC HEADSPACE GAS CHROMATOGRAPHY
MS 2069:2008
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies the headspace gas chromatography (GC) involves in the determination of volatile components in a polymer solution by gas chromatography of a vapor phase in thermal equ ....Read more ilibrium with the sample matrix. Volatiles in finely ground insoluble polymers can also be determined with and without an extracting solvent. 
This practice provides two procedures:

Procedure A—Automatic headspace analysis.

Procedure B—Manual injection headspace analysis.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use. Specific precautionary statements are given in Section 6.

NOTE 1—There is no equivalent ISO standard.
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TEST METHOD FOR RESIDUES IN LIQUEFIED PETROLEUM (LP) GASES
MS 2068:2008
Status : Original
Format : PDF

This Malaysian Standard covers the determination of extraneous materials weathering above 38°C that are present in liquefied petroleum gases. The extraneous materials will generally be dissolved in t ....Read more he LPG, but may have phase-separated in some instances. 
Liquefied petroleum gases that contain certain anti-icing additives can give erroneous results by this test method.

Although this test method has been used to verify cleanliness and lack of heavy contaminants in propane for many years, it might not be sensitive enough to protect some equipment from operational problems or increased maintenance. A more sensitive test, able to detect lower levels of dissolved contaminants, could be required for some applications.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior
Close

RM 15.00

Document will be sent via email



 Add To Cart

TEST METHOD FOR VAPOR PRESSURE OF LIQUEFIED PETROLEUM GASES (LPG) (EXPANSION METHOD)
MS 2067:2008
Status : Original
Format : PDF

This Malaysian Standard specifies the use of automatic vapor pressure instruments to determine the vapor pressure of liquefied petroleum gas products at a temperature of 37.8C, vapor to liquid ratio o ....Read more f 0.5:1, and pressures from 200 to 1550 kPa on a sample volume of 3.33 mL. 
This test method is applicable to the determination of vapor pressures of liquefied petroleum gas products at temperatures from 37.8 to 70°C, vapor to liquid ratios of 0.1:1 to 4:1, and pressures up to 3500 kPa; however, the precision of the test method (see Section 15) has only been determined for a vapor to liquid ratio of 0.5:1, at a temperature of 37.8°C, and a pressure range from 300 to 1500 kPa.

NOTE 1—This test method is not intended to determine the true vapor pressure of LPG samples, but rather determine and report the vapor pressure of LPG at the 37.8°C temperature and 0.5:1 vapor to liquid ratio as the Test Method D 1267 method.

NOTE 2—This test method is not a true vapor pressure method and will not
Close

RM 15.00

Document will be sent via email



 Add To Cart

TEST METHOD FOR DENSITY OR RELATIVE DENSITY OF LIGHT HYDROCARBONS BY PRESSURE HYDROMETER
MS 2065:2008
Status : Original
Format : PDF

This Malaysian Standard specifies the determination of the density or relative density of light hydrocarbons including liquefied petroleum gases (LPG) having Reid vapour pressures exceeding 101.325 kP ....Read more a (14.696 psi). 
The prescribed apparatus should not be used for materials having vapor pressures higher than 1.4 MPa (200 psi) at the test temperature. This pressure limit is dictated by the type of equipment. Higher pressures may apply to other equipment designs.

The values in SI units are to be regarded as the standard. The values in parentheses are for information only. Both SI and customary units have been rounded so that they may not be exactly equivalent.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Close

RM 15.00

Document will be sent via email



 Add To Cart

TEST METHOD FOR DRYNESS OF PROPANE (VALVE FREEZE METHOD)
MS 2064:2008
Status : Withdrawal without replacement
Format : PDF

This Malaysian Standard covers the measurement of the dryness of propane-type products such as, but not limited to, commercial propane.
Note 1- This Malaysian Standard is not applicable to prop ....Read more ane-type products containing antifreeze agents. However, the relative freeze times of such materials tested by this procedure may be an indication of the tendency of these products to cause freezing in pressure reducing regulators.

The values stated in SI units are to be regarded as the standard. The values in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. If is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establis
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




TEST METHOD FOR HYDROGEN SULFIDE IN LIQUEFIED PETROLEUM (LP) GASES (LEAD ACETATE METHOD)
MS 2063:2008
Status : Withdrawn
Format : PDF

This Malaysian Standard covers the detection of hydrogen sulfide in liquefied petroleum (LP) gases. The sensitivity of the test is about 4 mg/m3 (0.15 to 0.2 grain of hydrocarbon sulfide per 100 ft3) ....Read more of gas. 
The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only.

This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




ANISEED (PIMPINELLA ANISUM LINNAEUS) - SPECIFICATION (ISO 7386:1984, MOD)
MS 2062:2007
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for whole aniseed (Pimpinella anisum Linnaeus).

RM 15.00

Document will be sent via email



 Add To Cart

DURABILITY OF RUBBER GLOVES – TEST METHOD
MS 2061:2008
Status : Original
Format : PDF

This Malaysian Standard specifies the test method to determine the durability of rubber gloves. 

RM 15.00

Document will be sent via email



 Add To Cart

Small steam sterilizers
MS 2060:2008 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the performance requirements and test methods for small steam sterilizers and sterilization cycles which are used for medical purposes or for materials that are likel ....Read more y to come into contact with blood or body fluids. 
This Malaysian Standard applies to automati cally controlled small steam sterilizers that generate steam using electrical heaters or use steam that i s generated by a system external to the sterilizer.

This Malaysian Standard ap plies to small steam sterilizers used pri marily for the sterilization of medical devices and unable to accommodate a sterilizati on modul e (30 0 mm × 300 mm × 600 mm) and with a chamber volume not exceeding 60 litres.