ELECTRIC CABLE AND WIRE - POLYVINYL CHLORIDE (PVC) INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON-SHEATHED CABLES FOR FIXED WIRING
MS 2112-3:2009
Status : Original
Format : PDF

This Malaysian Standard details the particular specifications for PVC insulated single -core non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V a.c. 
The type ....Read more s of cables included in the standard is MS IV 01 - light PVC sheathed flexible cable. Close

RM 45.00

Document will be sent via email



 Add To Cart

ELECTRIC CABLE AND WIRE - POLYVINYL CHLORIDE (PVC) INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2: TEST METHODS
MS 2112-2:2009
Status : Original
Format : PDF

This Malaysian Standard applies to the methods of carry out the tests specified on cables with insulation, and sheath if any, based on PVC, of rated voltages up to and including 450/750 V used in powe ....Read more r installation of nominal voltages not exceeding 450/750 V a.c. 
The tests are applicable to the types of cables are given in the particular specifications (MS 2112-3, MS 2112-4, MS 2112-5 and MS 2112-6).
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electric cable and wire - Polyvinyl chloride (PVC) insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods AMENDMENT 1
MS 2112-2:2009, AMD. 1:2015
Status : Amendment 1
Format : PDF

This Malaysian Standard applies to the methods of carry out the tests specified on cables with insulation, and sheath if any, based on PVC, of rated voltages up to and including 450/750 V used in powe ....Read more r installation of nominal voltages not exceeding 450/750 V a.c. 
The tests are applicable to the types of cables are given in the particular specifications (MS 2112-3, MS 2112-4, MS 2112-5 and MS 2112-6).
Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

Electric cable and wire - Polyvinyl chloride (PVC) insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables AMENDMENT 1
MS 2112-5:2009, AMD. 1:2017
Status : Amendment 1
Format : PDF

This Malaysian Standard details the particular specifications for polyvinyl chloride insulated flexible cables of rated voltages up to and including 450/750 V a.c. 
The types of cables include ....Read more d in the standard are:

a) MS VVF 20 - light PVC sheathed flexible cable;
b) MS VVF 21 - ordinary PVC sheathed flexible cable;
c) MS VVF 22 - heat resistant light PVC sheathed flexible cable - 90 oC;
d) MS VVF 23 - heat resistant ordinary PVC sheathed flexible cable - 90 oC;
e) MS VVF 24 - heat resistant light PVC sheathed flexible cable - 105 oC; and
f) MS VVF 25 - heat resistant ordinary PVC sheathed flexible cable - 105 oC.
Close

FREE

Document will be sent via email



Please Login to enable MS to be send via email

Electric cable and wire: 19/33 (36) kV single core XLPE insulated cable - Armoured
MS 2111:2007 (CONFIRMED:2014)
Status : Original
Format : PDF

This Malaysian Standard specifies the construction, dimensions, test, drumming and packaging requirements of single core power cables with extruded cross-linked polyethylene(XLPE) insulation for opera ....Read more tion at rated voltage 19/33 (36) kV. 
The cables as prescribe are generally use for medium voltage, fixed installation system for distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. Welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where applicable.
Close

RM 15.00

Document will be sent via email



 Add To Cart

Electric cable and wire: 19/33 (36) kV single core XLPE insulated cable - Non-armoured
MS 2110:2007 (CONFIRMED:2014)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the construction, dimension and test requirements of single-core power cables with extruded cross-linked polyethylene (XLPE) insulation for operation at rated voltage ....Read more 19/33 (36) kV. 
The cables as prescribe are generally use for medium voltage, fixed installation system for distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. Welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where applicable.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electric cable and wire: 6.35/11 (12) kV single core XLPE insulated cable - Armoured
MS 2109:2007 (CONFIRMED:2013)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the construction, dimensions, test, drumming and packaging requirements of single core power cables with extruded cross-linked polyethylene(XLPE) insulation for opera ....Read more tion at rated voltage 6.35/11 (12) kV. 
The cables as prescribe are generally use for medium voltage, fixed installation system for distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. Welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where applicable.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electric cable and wire: 6.35/11 (12) kV single core XLPE insulated cable - Non-armoured
MS 2108:2007 (CONFIRMED:2014)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the construction, dimensions and test requirements of single-core power cables with extruded cross-linked polyethylene (XLPE) insulation for operation at rated voltag ....Read more e 6.35/11 (12) kV. 
The cables as prescribed are generally use for medium voltage, fixed installation system for the distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where available.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electric cable and wire: 600/1 000 (Um = 1 200) V multi core XLPE insulated cable - Armoured
MS 2107:2007 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies construction, dimension and test requirements of cross-linked polyethylene (XLPE) insulated multi core cables, Armoured for operation at rated voltage 600/1 000 (1 20 ....Read more 0) V. 
The cables as prescribe are generally use for low voltage, fixed installation system for distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where applicable.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Electric cable and wire: 600/1 000 (Um = 1 200) V multi core XLPE insulated cable - Non-armoured
MS 2106:2007 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies the construction, dimension and test requirements of crosslinked 
polyethylene (XLPE) insulated multi core cables, non-armoured for operation at rated voltage ....Read more 600/1 000 (1 200) V.

The cables as prescribed are generally use for low voltage, fixed installation system for the distribution network. It is not intended for use in prolonged water logged conditions and for specialised applications (e.g. welding, crane lifting, mines, aerial), which are covered by other Malaysian Standards, where available.