ELECTRIC CABLE AND WIRE - POLYVINYL CHLORIDE (PVC) INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 3: NON-SHEATHED CABLES FOR FIXED WIRING
MS 2112-3:2009Status : Original
Format : PDF
This Malaysian Standard details the particular specifications for PVC insulated single -core non-sheathed cables for fixed wiring of rated voltages up to and including 450/750 V a.c.
The type
....Read more
ELECTRIC CABLE AND WIRE - POLYVINYL CHLORIDE (PVC) INSULATED CABLES OF RATED VOLTAGES UP TO AND INCLUDING 450/750 V - PART 2: TEST METHODS
MS 2112-2:2009Status : Original
Format : PDF
This Malaysian Standard applies to the methods of carry out the tests specified on cables with insulation, and sheath if any, based on PVC, of rated voltages up to and including 450/750 V used in powe ....Read more
Electric cable and wire - Polyvinyl chloride (PVC) insulated cables of rated voltages up to and including 450/750 V - Part 2: Test methods AMENDMENT 1
MS 2112-2:2009, AMD. 1:2015Status : Amendment 1
Format : PDF
This Malaysian Standard applies to the methods of carry out the tests specified on cables with insulation, and sheath if any, based on PVC, of rated voltages up to and including 450/750 V used in powe ....Read more
Electric cable and wire - Polyvinyl chloride (PVC) insulated cables of rated voltages up to and including 450/750 V - Part 5: Flexible cables AMENDMENT 1
MS 2112-5:2009, AMD. 1:2017Status : Amendment 1
Format : PDF
This Malaysian Standard details the particular specifications for polyvinyl chloride insulated flexible cables of rated voltages up to and including 450/750 V a.c.
The types of cables include
....Read more
Electric cable and wire: 19/33 (36) kV single core XLPE insulated cable - Armoured
MS 2111:2007 (CONFIRMED:2014)Status : Original
Format : PDF
This Malaysian Standard specifies the construction, dimensions, test, drumming and packaging requirements of single core power cables with extruded cross-linked polyethylene(XLPE) insulation for opera ....Read more
Electric cable and wire: 19/33 (36) kV single core XLPE insulated cable - Non-armoured
MS 2110:2007 (CONFIRMED:2014)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the construction, dimension and test requirements of single-core power cables with extruded cross-linked polyethylene (XLPE) insulation for operation at rated voltage ....Read more
Electric cable and wire: 6.35/11 (12) kV single core XLPE insulated cable - Armoured
MS 2109:2007 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the construction, dimensions, test, drumming and packaging requirements of single core power cables with extruded cross-linked polyethylene(XLPE) insulation for opera ....Read more
Electric cable and wire: 6.35/11 (12) kV single core XLPE insulated cable - Non-armoured
MS 2108:2007 (CONFIRMED:2014)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies the construction, dimensions and test requirements of single-core power cables with extruded cross-linked polyethylene (XLPE) insulation for operation at rated voltag ....Read more
Electric cable and wire: 600/1 000 (Um = 1 200) V multi core XLPE insulated cable - Armoured
MS 2107:2007 (CONFIRMED:2023)Status : 2nd Confirmation
Format : PDF
This Malaysian Standard specifies construction, dimension and test requirements of cross-linked polyethylene (XLPE) insulated multi core cables, Armoured for operation at rated voltage 600/1 000 (1 20 ....Read more
Electric cable and wire: 600/1 000 (Um = 1 200) V multi core XLPE insulated cable - Non-armoured
MS 2106:2007 (CONFIRMED:2023)Status : 2nd Confirmation
Format : PDF
This Malaysian Standard specifies the construction, dimension and test requirements of crosslinked
polyethylene (XLPE) insulated multi core cables, non-armoured for operation at rated voltage
....Read more