STATIONARY SOURCE EMISSIONS - DETERMINATION OF MASS CONCENTRATION OF SULFUR DIOXIDE - ION CHROMATOGRAPHY METHOD (ISO 11632:1998 (2004), IDT)
MS ISO 11632:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a method for the determination of the mass concentration of sulfur dioxide emitted from combustion facilities and technical processes, and defines the most important ....Read more performance characteristics. 
The method described in this Malaysian Standard has been tested for a sulfur dioxide concentration range of 6 mg/m3 to 333 mg/m3 with sampling periods of 30 min. It is applicable to mass concentrations of sulfur dioxide exceeding this range by carrying out an appropriate dilution of the sample solutions prior to the analysis or by using larger volumes of absorption solution, and to sulfur dioxide concentrations below this range by extending the sampling period.

This Malaysian Standard is applicable to the analysis of samples containing negligible levels of sulfur trioxide and volatile sulfates (< 5 % of the expected sulfur dioxide concentration), and ammonia (< 5 mg/m3). All concentrations are based on dry gas at a temperature of 273,2 K and pressure of 101,
Close

RM 30.00

Document will be sent via email



 Add To Cart

Gas cylinders - Procedures for change of gas service (ISO 11621:1997, IDT)
MS 11621:2008 (CONFIRMED:2015)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard applies to seamless steel, aluminium alloy and welded steel refillable cylinders of all sizes, including large cylinders (water capacity greater than 150 L). It provides genera ....Read more l requirements and procedures to be considered whenever a cylinder is being transferred from one gas service to another for permanent and liquefied gases.It does not apply to cylinders for dissolved acetylene, radioactive gases or gases listed in group G of table 1. Close

RM 30.00

Document will be sent via email



 Add To Cart

Reciprocating internal combustion compression-ignition engines - Apparatus for measurement of the opacity and for determination of the light absorption coefficient of exhaust gas (ISO 11614:1999, MOD)
MS 11614:2017
Status : Original
Format : PDF

This Malaysian Standard specifies the general requirements and the installation of apparatus for measurement of the opacity and for the determination of the light absorption coefficient of exhaust gas ....Read more from internal combustion engines (not confined to road vehicles). These instruments are known as opacimeters. Close

RM 105.00

Document will be sent via email



 Add To Cart

PROTECTIVE CLOTHING FOR FIREFIGHTERS – LABORATORY TEST METHODS AND PERFORMANCE REQUIREMENTS (ISO 11613:1999, IDT)
MS ISO 11613:2005
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies test methods and minimum requirements for protective clothing to be worn during firefighting and associated activities where there is a risk of heat and/or flame 
....Read more /> This Malaysian Standard covers the general clothing design, the minimum performance levels of
the materials used, and the methods of test for determining these performance levels. Clauses 4 and 5 define two separate sets of design and performance requirements.

This Malaysian Standard does not cover special clothing for use in other high risk situations such as specialized fire fighting, or clothing for use in long term firefighting operations in high ambient temperature, for example brush, wildland, or forest firefighting. It does not cover protection for the head, hands and feet or protection against other hazards, for example chemical, biological, radiation and electrical hazards. These aspects may be dealt with in other standards.

Selection of the appropriate system of clothing is dep
Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




DENTISTRY – TOOTHPASTE – REQUIREMENTS, TEST METHODS AND MARKING (ISO 11609:1995, IDT)
MS ISO 11609 : 2003
Status : Original
Format : PDF

This Malaysian Standard specifies requirements and test methods for physical and chemical properties, and for the marking and/or labelling of tooth-pastes for daily use by the public with a toothbrush ....Read more to promote oral hygiene.  Close

RM 30.00

Document will be sent via email



 Add To Cart

Packaging for terminally sterilized medical devices - Part 2: Validation requirements for forming, sealing and assembly processes (First revision) (ISO 11607-2:2006, IDT)
MS ISO 11607-2:2009 (CONFIRMED:2015)
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies the requirements for development and validation of processes for packaging medical devices that are terminally sterilized. These processes include forming, sealing an ....Read more d assembly of preformed sterile barrier systems, sterile barrier systems and packaging systems. 
This Malaysian Standard is applicable to industry, to health care facilities, and wherever medical devices are packaged and sterilized.

This Malaysian Standard does not cover all requirements for packaging medical devices that are manufactured aseptically. Additional requirements may also be necessary for drug/device combinations.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Packaging for terminally sterilized medical devices - Part 1: Requirements for materials, sterile barrier systems and packaging systems (First revision) (ISO 11607-1:2006, IDT)
MS ISO 11607-1:2009 (CONFIRMED:2015)
Status : 1st Revision
Format : PDF

This Malaysian Standard specifies the requirements and test methods for materials, preformed sterile barrier systems, sterile barrier systems and packaging systems that are intended to maintain steril ....Read more ity of terminally sterilized medical devices until the point of use. 
This standard is applicable to industry, to health care facilities, and wherever medical devices are placed in sterile barrier systems and sterilized.

This standard does not cover all requirements for sterile barrier systems and packaging systems for medical devices that are manufactured aseptically. Additional requirements might also be necessary for drug/device combinations.

This standard does not describe a quality assurance system for control of all stages of manufacture.
Close

RM 60.00

Document will be sent via email



 Add To Cart

JEWELLERY - SAMPLING OF PRECIOUS METAL ALLOYS FOR AND IN JEWELLERY AND ASSOCIATED PRODUCTS (ISO 11596:2008, IDT)
MS ISO 11596:2010
Status : Original
Format : PDF

This Malaysian Standard specifies a method of sampling precious metal jewellery alloys for the determination of the precious metal content. It is applicable to raw materials, semi-finished products an ....Read more d finished products of the jewellery alloys of precious metals. The purpose of this Standard is to define all the operations needed to obtain samples intended for the determination of the precious metal content of a particular jewellery alloy. It is intended to be applied when sampling alloys are claimed to be homogeneous. 
This Malaysian Standard does not cover alloys of precious metals used in industrial products, coins qualified as legal tender, dentistry or decorative coatings on other material. It is not intended to apply to procedures employed for the purposes of production control or for the provision of samples other than for the determination of the precious metal content.
Close

RM 30.00

Document will be sent via email



 Add To Cart

STATIONARY SOURCE EMISSIONS - DETERMINATION OF THE MASS CONCENTRATION OF NITROGEN OXIDES - NAPHTHYLETHYLENEDIAMINE PHOTOMETRIC METHOD (ISO 11564:1998 (2004), COR. 1:2000, IDT)
MS ISO 11564:2009 (CONFIRMED:2023)
Status : 2nd Confirmation
Format : PDF

This Malaysian Standard specifies a photometric method for the determination of the mass concentration of nitrogen oxides in exhaust gases from ducts or chimneys. 
The method is applicable to ....Read more the determination of the mass concentration of nitrogen oxides in exhaust gases from combustion processes, processes for surface treatment of metals and from organic chemical reactions, if necessary after removal by washing, in-furnace reduction and/or catalytic denitration, prior to their dispersion into the atmosphere.

This Malaysian Standard is applicable to the concentration range 5 mg/m3 to 1000 mg/m3 as NO2 for a sample gas volume of 1000 ml.

For gas concentrations greater than 1000 mg/m3, the determination of sample gas concentrations up to 5000 mg/m3 can be performed by diluting the sample solution or by taking an aliquot of the sample solution.

This Malaysian Standard is not applicable to the determination of dinitrogen monoxide (N2O).
Close

RM 45.00

Document will be sent via email



 Add To Cart

IRON ORES - DETERMINATION OF TIN CONTENT - FLAME ATOMIC ABSORPTION SPECTROMETRIC METHOD (FIRST REVISION) (ISO 11534:2006, IDT)
MS ISO 11534:2011 (CONFIRMED:2025)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies specifies a flame atomic absorption spectrometric method for the determination of the mass fraction of tin in iron ores. This method is applicable to mass fractions o ....Read more f tin between 0.001 % and 0.015 % in natural iron ores, iron ore concentrates and agglomerates, including sinter products Close