Power transformers - Part 11: Dry-type transformers (IEC 60076-11:2004, MOD)
MS 60076-11:2012Status : Original
Format : PDF
This Malaysian Standard specifies dry-type power transformers (including auto-transfomers) having values of highest voltage for equipment up to and including 36 kV and at least one winding operating a ....Read more
Power transformers - Part 12: Loading guide for dry-type power transformers (IEC 60076-12:2008, IDT)
MS IEC 60076-12:2012Status : Original
Format : PDF
This Malaysian Standard is applicable to dry-type transformers according to the scope of IEC 60076-11. It provides the means to estimate ageing rate and consumption of lifetime of the transformer insu ....Read more
Power transformers - Part 10: Determination of sound levels (IEC 60076-10:2001, IDT)
MS IEC 60076-10:2005Status : Original
Format : PDF
This Malaysian Standards defines sound pressure and sound intensity measurement methods by which sound power levels of transformers, reactors and their associated cooling auxiliaries may be determined ....Read more
POWER TRANSFORMERS - PART 5: ABILITY TO WITHSTAND SHORT CIRCUIT(IEC 60076-5:2000, IDT)
MS IEC 60076-5:2005Status : Original
Format : PDF
This Malaysian Standards identifies the requirements for power transformers to sustain without damage the effects of over currents originated by external short circuits. It describes the calculation p ....Read more
POWER TRANSFORMERS - PART 2: TEMPERATURE RISE(IEC 60076-2:1993, IDT)
MS IEC 60076-2:2005Status : Original
Format : PDF
This part of Malaysian Standard IEC 76 identifies transformers according to their cooling methods, defines temperature-rise limits and details the methods of test for temperature-rise measurements. It ....Read more
Power transformers - Part 3: Insulation levels, dielectric tests and external clearances in air (IEC 60076-3: 2000, IDT)
MS IEC 60076-3:2005 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
his Malaysian Standard applies to single-phase and three-phase oil-immersed power transformers (including auto-transformers), with the exception of certain small and special transformers, as defined i ....Read more
Power transformers - Part 4: Guide to the lightning impulse and switching impulse testing - Power transformers and reactors (IEC 60076-4:2002, IDT)
MS IEC 60076-4:2005 (CONFIRMED:2013)Status : 1st Confirmation
Format : PDF
This Malaysian Standard gives guidance and explanatory comments on the existing procedures for
lightning and switching impulse testing of power transformers to supplement the requirements of ....Read more
Power transformers - Part 1: General (First revision) (IEC 60076-1:2011, MOD)
MS 60076-1:2015Status : 1st Revision
Format : PDF
This Malaysian Standard applies to three-phase and single-phase power transformers (including auto-transformers) with the exception of certain categories of small and special transformers. For those c ....Read more
Insulation co-ordination - Part 4: Computational guide to insulation co-ordination and modelling of electrical networks
MS 60071-4:2012Status : Original
Format : PDF
This Malaysian Standard gives guidance on conducting insulation co-ordination studies which propose internationally recognised recommendations - for the numerical modelling of electrical systems, and ....Read more
Insulation co-ordination - Part 5: Procedures for high-voltage direct current (HVDC) converter stations (IEC/TS 60071-5:2002, MOD)
MS 60071-5:2012Status : Original
Format : PDF
This Malaysian Standard specifies guidance on the procedures for insulation co-ordination of high-voltage direct current (HVDC) converter stations, without prescribing standardised insulation levels. ....Read more