• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 3: Fittings (First revision) (ISO 15876-3:2017 and its AMENDMENT 1:2020 and AMENDMENT 2:2021, MOD)
MS 2763-3:2024
Status : 1st Revision
Format : PDF

This document specifies the characteristics of fittings for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water, wh ....Read more ether or not intended for human consumption (domestic systems) and for heating systems under design pressures and temperatures according to the class of application (see ISO 15876-1).

The designation polybutene is used together with the abbreviation PB throughout this document.

This document covers a range of service conditions (application classes) and design pressure classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876-1:2016, Table 1, this document does not apply.

NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.
Close

RM 75.00

Document will be sent via email



 Add To Cart

Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 2: Pipes (First revision) (ISO 15876-2:2017 and its AMENDMENT 1:2020, MOD)
MS 2763-2:2024
Status : 1st Revision
Format : PDF

This document specifies the characteristics of pipes for polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whethe ....Read more r or not intended for human consumption (domestic systems), and for heating systems, under design pressures and temperatures appropriate to the class of application (see ISO 15876-1).

The designation polybutene is used together with the abbreviation PB throughout this document.

This document covers a range of service conditions (application classes), design pressures and pipe dimension classes. For values of TD, Tmax and Tmal in excess of those in ISO 15876-1, this document does not apply.

NOTE 1 It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this document.

In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, their joints and to joints with components of PB, other plastics and non-plastics materials intended to be used for hot and cold water installations. It is applicable to pipes with or without (a) barrier layer(s).

NOTE 2 In the case of plastics pipes provided with a thin barrier layer, e.g. to prevent or greatly diminish the diffusion of gases and the transmission of light into or through the pipe wall, the design stress requirements are totally met by the base polymer (PB).
Close

RM 60.00

Document will be sent via email



 Add To Cart

Plastics piping systems for hot and cold water installations - Polybutylene (PB) - Part 1: General (First revision) (ISO 15876-1:2017, MOD)
MS 2763-1:2024
Status : 1st Revision
Format : PDF

This document specifies the general aspects of polybutene-1 (PB-1) piping systems intended to be used for hot and cold water installations within buildings for the conveyance of water whether or not i ....Read more ntended for human consumption (domestic systems) and for heating systems, under design pressures and temperatures according to the class of application (see Table 1).

The designation polybutene is used together with the abbreviation PB throughout this document.

This document covers a range of service conditions (application classes) and design pressure and pipe dimension classes. Values of TD, Tmax and Tmal in excess of those in Table 1 do not apply.

NOTE It is the responsibility of the purchaser or specifier to make the appropriate selections from these aspects, taking into account their particular requirements and any relevant national regulations and installation practices or codes.

It also specifies the test parameters for the test methods referred to in this document.

In conjunction with the other parts of ISO 15876, this document is applicable to PB pipes, fittings, their joints and to joints with components of other plastics and non-plastics materials intended to be used for hot and cold water installations.
Close

RM 30.00

Document will be sent via email



 Add To Cart

Water dispenser for household use - Method of measuring the performance
MS 2799:2024
Status : Original
Format : PDF

This Malaysian Standard specifies method for measuring the performance of storage and instant hot & cold water dispensers with a maximum rated voltage does not exceeding 250 V for household use.

RM 45.00

Document will be sent via email



 Add To Cart

Natural rubber and butyl rubber inner tubes for motorised vehicles - Specification (Second revision)
MS 868:2024
Status : 2nd Revision
Format : PDF

This Malaysian Standard applies to inner tubes natural rubber and butyl rubber for pneumatic tyres.

RM 30.00

Document will be sent via email



 Add To Cart

Goods vehicles – Construction of truck tanker body - Requirements
MS 2755:2024
Status : Original
Format : PDF

This Malaysian Standard specifies requirements for the construction of truck tanker body for transporting solid (powdery or granular) and liquid products. This standard is applicable to vehicles categ ....Read more ory N and O as classified in accordance with MS 1822. This document does not apply to truck tankers that carrying dangerous goods.

This standard is not intended to be prescriptive in nature; it provides reasonable and practicable guidance in construction of truck tanker body including mounting and safety features requirements.
Close

RM 60.00

Document will be sent via email



 Add To Cart

Vocabulary related to rattan materials and products (ISO 23066:2021, IDT) (Published by Department of Standards Malaysia in 2024)
MS ISO 23066:2021
Status : Original
Format : PDF

This document defines terms relating to rattan source plants, materials, intermediate rattan products and rattan products.

This document is applicable to rattan materials and products i ....Read more n production and trade. Close

RM 30.00

Document will be sent via email



 Add To Cart

Electrical accessories – Circuit-breakers for overcurrent protection for household and similar installations – Part 2: Circuitbreakers for AC and DC operation (IEC 60898-2:2016, IDT) (Published by Department of Standards Malaysia in 2024)
MS IEC 60898-2:2016
Status : Original
Format : PDF

Clause 1 of IEC 60898-1:2015 is applicable except as follows:

Addition at the end of the first paragraph:

This standard gives additional requirements for single- and two- ....Read more pole circuit-breakers which, in addition to the above characteristics, are suitable for operation with direct current, and have a rated DC voltage not exceeding 220 V for single-pole and 440 V for two-pole circuit-breakers, a rated current not exceeding 125 A and a rated DC short-circuit capacity not exceeding 10 000 A.

NOTE This standard applies to circuit-breakers able to make and break both alternating current and direct current.

Delete the last two paragraphs.
Close

RM 45.00

Document will be sent via email



 Add To Cart

Electrical accessories – Circuit-breakers for overcurrent protection for household and similar installations – Part 1: Circuitbreakers for a.c. operation (Second revision) (IEC 60898-1:2015+AMD1:2019 CSV, IDT) (Published by Department of Standards Malaysia in 2024)
MS IEC 60898-1:2019
Status : 2nd Revision
Format : PDF

This part of IEC 60898 applies to a.c. air-break circuit-breakers for operation at 50 Hz, 60 Hz or 50/60 Hz, having a rated voltage not exceeding 440 V (between phases), a rated current not exceeding ....Read more 125 A and a rated short-circuit capacity not exceeding 25 000 A.

As far as possible, it is in line with the requirements contained in IEC 60947-2.

NOTE 1 Additional requirements are necessary for circuit-breakers used in locations having more severe
overvoltage conditions.
Close

RM 225.00

Document will be sent via email



 Add To Cart

Site investigations - Code of practice (First revision)
MS 2038:2024
Status : 1st Revision
Format : PDF

This Malaysian Standard gives recommendations for the investigation of sites for the purposes of assessing their suitability for the construction of civil engineering and building works and of acquiri ....Read more ng knowledge of the characteristics of a site that could affect the design and construction of such work and the security of neighbouring land and property.

NOTE: The use of soil and rock as construction materials is only treated briefly; further information is given in BS 6031.

This standard provides guidance on the application of MS EN 1997-1 and MS EN 1997-2 and the related test standards cited therein.

It does not provide guidance on investigations for contamination or naturally elevated concentrations of potentially hazardous substances (these are dealt with in BS 10175). Nor does it provide guidance on investigations for ground gas (these are dealt with in BS 8576). However, it does provide guidance on the integration of geotechnical investigations with investigations for contamination or ground gas and other types of investigations (e.g. archaeological).
Close

RM 495.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • ...
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • ...
  • 585
  • 586
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.