• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • Sign In
  •  Cart ()
Search Malaysian Standard (MS)
 Advanced Search Search




Synthetic resin adhesives (phenolic and aminoplastic) for plywood - Specification (First revision)
MS 908:2012 (CONFIRMED:2024)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements and methods of test for adhesives
based on synthetic resins of the phenolic and aminoplastic types with or without additional hardeners. The ....Read more synthetic resin adhesives covered by this standard are intended for use in the plywood industry. Close

RM 30.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR LATEX EMULSION PAINT FOR INTERIOR USE
MS 903 : 1984
Status : Original
Format : PDF

This Malaysian Standard specifiesanair-
drying latex emulsion paint suitable for interior
use only. The paint is normally intended for use on
masonry surfaces including concrete,bric ....Read more k
stucco,concrete block and asbestos-cement
shingle sandsidings, and for recoating of
previously the surface
is in sound condition and suitable for receiving
such a coating. It may also be used on suitably
primed metal and wood surfaces
Close

RM 15.00

Document will be sent via email



 Add To Cart

SPECIFICATION FOR COPPER NAPHTHENATE wood PRESERVATIVE
MS 878 : 1984
Status : Withdrawn
Format : PDF

This Malaysian Standard specifies requirements for copper naphthenate wood preservatives which consist essentially of a solution. in a petroleum distill ....Read more ate of boiling range 1 40°C to 270°C, of copper salts of naphthenic acids. This specification covers the composition of the preservative and general recommendations on application. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




SPECIFICATION FOR TRIBUTYLTIN OXIDE wood PRESERVATIVE
MS 836:1983
Status : Withdrawn
Format : PDF

This Malaysian Standard specification prescribes requirements for light organic solvent wood preservatives which contain tributyltin oxide fortified wit ....Read more h an insecticide, gamma hexachlorocyclohexane. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




METHOD FOR THE QUANTITATIVE ANALYSIS OF BIS(TRI-N-BUTYLTIN) OXIDE PRESERVATIVE FORMULATIONS AND TREATED TIMBER : DETERMINATION OF TOTAL TIN
MS 835 : 1984
Status : Withdrawn
Format : PDF

This Malaysian Standard details procedures for the determination of the total tin content present in solutions and in treated wood containing bis(tri-n- ....Read more butyltin)oxide. The methods have been found suitable for the determination of tin in the presence of the following: chloronaphthalenes; copper naphthenate: dieldrin (HEOD); ‘y — hexachiorocyclohexane ( y —HCH, lindane); pentachlorophenyl laurate; pentach(orophenol and other chlorophenols; 2—phenylphenol; zinc naphthenate; water-repellent waxes and resins.

It is assumed that all the tin determined by these methods has been derived from bis(tri-n-butyltin)oxide and hence the tin content is expressed in terms of bis(tri-n-butyltin)oxide.
With aged samples of treated wood, it is occasionally difficult to acid extract all the tin, particularly if iron or some other Cations are present. The method described in 2.4.4 has been shown to ensure that, in all cases, the proportion of tin not extracted is unlikely to affect the validity of the dete
Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




METHOD FOR THE QUANTITATIVE ANALYSIS OF COPPER NAPTHENATE PRESERVATIVE FORMULATIONS AND TREATED TIMBER
MS 834 : 1984 (CONFIRMED:2024)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard details procedures for the determination of copper naphthenate, expressed as the amount of copper present, in preservatives and in treated timber containing this preservative.< ....Read more br />
The methods have been found suitable for the determination of copper in the presence of tributyltin oxide, pentachlorophenol, o-phenylphenol, monochloronaphthalene, polych)oronaphthalene, ‘y -HCH, dieldrin. zinc naphthenate, potassium salts and sodium salts. The wood sample may be in the form of sawdust, wood flour, or thin sections.

The procedure for the analysis of preservatives has been primarily designed for solutions complying with the requirements of MS 878~.For samples of other compositions it may be necessary to make adjustments so that the solutions are within the analytical range and in the AAS determination, sample solution and standard solution have similar solution matrix. It is difficult to make recommendations as to the quantity of sample to be taken in the case of treated
Close

RM 15.00

Document will be sent via email



 Add To Cart

Qualitative analysis of wood preservatives and treated timbers - Test method (First revision)
MS 833:2014 (CONFIRMED:2020)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard details the procedures for the detection of preservative materials commonly found in organic solvent type and water-borne type preservative solutions and in preservative-treate ....Read more d wood Close

RM 30.00

Document will be sent via email



 Add To Cart

METHOD FOR THE QUALITATIVE ANALYSIS OF wood PRESERVATIVES AND TREATED TIMBER
MS 833 : 1984
Status : Withdrawn
Format : PDF

This Malaysian Standard details procedures for the detection of preservative materials commonly found in organic solvent type and water-borne type preservative solutions and in preservative-treated ....Read more pan style='background-color : #c4c5cf'>wood.

The complex nature of the tar oil type preservatives precludes the use of a specific qualitative test for this group, although some indication of theIr presence may be provided by odour and appearance characteristics.

The procedures described in this standard will frequently be applied before carrying out quantitative analyses using methods described in other standards. Two types of qualitative test are described, those carried out directly on timber sections and those requiring prior preparation of an extract from the timber sample. Some preservative materials can be detected by either type of method, others by only one of them. In addition to the detection of preservative materials, the spray tests described may be used to estimate the penetration of the preservatives. Close

NOT FOR SALE

"Please contact us if you are interested to purchase for reference."




SPECIFICATION FOR wood PRESERVATION BY MEANS OF PRESSURE CREOSOTING
MS 734 : 1981
Status : Withdrawn
Format : PDF

This Malaysian Standard covers the preservation of timber by the pressure creosoting processes. These consist essentially of immersing the timber completely in creosote contained in a closed vessel an ....Read more d subjecting it to a pressure greater than atmospheric. Close

NOT FOR SALE

Please contact us if you are interested to purchase for reference.




wood PRESERVATIVES FOR COPPER/CHROMIUM/ARSENIC (CCA) - SPECIFICATION (SECOND REVISION)
MS 733:2008 (CONFIRMED:2020)
Status : 1st Confirmation
Format : PDF

This Malaysian Standard specifies the requirements for water-borne wood preservatives, which consist essentially of mixtures in compounds of copper, chr ....Read more omium and arsenic (CCA). This specification covers two mixtures of composition for preservatives, i.e. Type 1 and Type 2; and sampling procedures.

The chemical analysis and specification for the treatment of timber with CCA is as specified in MS 821 and MS 360 respectively.

CAUTION: Attention is drawn to the mandatory requirement that the CCA timber preservative marketed in Malaysia including their importation, manufacturing, sales and storage for sale shall be registered with the Pesticides Board under the Pesticides Act 1974.
Close

RM 15.00

Document will be sent via email



 Add To Cart

  • ‹
  • 1
  • 2
  • 3
  • 4
  • 5
  • 6
  • 7
  • 8
  • 9
  • 10
  • 11
  • 12
  • 13
  • ›
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.