CODE OF PRACTICE FOR STRUCTURAL USE OF TIMBER : PART 2 : PERMISSIBLE STRESS DESIGN OF SOLID TIMBER (FIRST REVISION)
MS 544 : PART 2 : 2001Status : Withdrawn
Format : PDF
This Part gives recommendations for the structural use of the Malaysian hardwood and softwood timber spe ....Read more
NOT FOR SALE
"Please contact us if you are interested to purchase for reference."wood-based panels - Part 2: Sampling and cutting of test pieces (First revision) (ISO 16999:2003, MOD)
MS 1787-2:2020Status : 1st Revision
Format : PDF
This Malaysian Standard specifies certain rules for the sampling and cutting of test pieces. This standard does not cover the sampling and cutting of test pieces for the derivation of characteristic v ....Read more
wood-based panels - Part 1: Determination of dimensions of panels (First revision) (ISO 16999:2003, MOD)
MS 1787-1:2020Status : 1st Revision
Format : PDF
This Malaysian Standard specifies a method for measuring the thickness, width and length, as well as the squareness, edge straightness and flatness of wood....Read more
METHOD FOR THE EVALUATION OF THE EFFECTIVENESS OF INSECTICIDAL AEROSOL AS CONTACT AND RESIDUAL INSECTICIDES : PLYwood PLAQUE METHOD
MS 1130:1989Status : Original
Format : PDF
1.1 This Malaysian Standard prescribes the method for evaluation of the effectiveness of
insecticidal aerosol as contact and residual insecticides against cockroaches.
1.2 This method prov ....Read more
Code of practice for structural use of timber - Part 5: timber joints (First revision)
MS 544-5:2018Status : 1st Revision
Format : PDF
This part of Malaysian Standard applies to joints in solid timbers fabricated with mechanical fasteners. These include joints fabricated with the following fasteners:
a) nails;
b) ....Read more
screws;
c) bolts;
d) coach screws;
e) split-ring connectors;
f) shear-plate connectors; and
g) steel dowels.
For mechanical fasteners used in connections for engineered timber components (e.g. glue laminated timber or glulam, laminated veneer lumber (LVL), etc.), guidance is recommended to be obtained from their manufacturers on whether the joint design values based on solid timber are applicable for their products.
NOTES:
1. Design rules for specialised and patented mechanical fasteners and for variants of conventional fasteners are not included in this standard.
2. This standard does not specifically cover glued timber-to-timber or timber-to-plywood connections as occurred in fabricated components such as stressed skin panels or plywood webbed beams. In such cases, joint design can be based on the timber components in the connection, provided that the joints are fabricated using a rigid, durable adhesive. Phenolic type adhesives meet these requirements. The design of fabricated components comprising glued connections is therefore based on the fact that with correct bonding practice and quality control, a joint is developed in which the adhesive bond strength and durability will be superior to the components comprising the joints. Reference may be made to Appendix C3 of AS 1720.1:2010, for information on methods for assessing the deformation of joints.
Code of practice for structural use of timber - Part 2: permissible stress design of solid timber (First revision)
MS 544-2:2017 (CONFIRMED:2022)Status : 1st Confirmation
Format : PDF
This part of Malaysian Standard describes recommendations for the structural use of the Malaysian hardwood and soft timber species in load bearing members. It includes recommendations on quality, grade stresses and modification factors applicable to these timbers when used as simple members, or as parts of built-up components, or as parts of structures incorporating other materials. It does not, and it is not intended to deal comprehensively with all aspects of timber construction. In particular, it does not cover well tried and traditional methods of timber construction which have been employed successfully over a long period of time.
Dressed timber, door jambs and general mouldings - Specification (First revision)
MS 1401:2018Status : 1st Revision
Format : PDF
This Malaysian Standard describes the specification and grading requirements applicable to dressed timber, door jambs and general mouldings of premium, standard and utility grades manufactured from tr ....Read more
Evaporation loss of lubricating oils by the Noack method - Test method (First revision)
MS 2031:2018Status : 1st Revision
Format : PDF
1.1 This test method covers three procedures for determining
the evaporation loss of lubricating oils (particularly engine
oils). Procedure A uses the Noack evaporative tester equipment;....Read more
Adhesives - Test methods for the evaluation and selection of adhesives for indoor wood products - Part 1: Resistance to delamination in non-severe environments (ISO 26842-1:2009, IDT)
MS ISO 26842-1:2011 (CONFIRMED:2020)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies guidelines for the selection, by means of delamination-resistance tests, of adhesives for use in wood products placed ....Read more
Adhesives - Test methods for the evaluation and selection of adhesives for indoor wood products - Part 2: Resistance to delamination in severe environments (ISO 26842-2:2009, IDT)
MS ISO 26842-2:2011 (CONFIRMED:2020)Status : 1st Confirmation
Format : PDF
This Malaysian Standard specifies guidelines for the selection, by means of delamination-resistance tests, of adhesives for use in wood products placed ....Read more