Measuring the effect on filterability of engine
oils after treatment with various amounts of
water and a long (6 h) heating time -
Test method
(First revision)
tendency
of an oil to form a precipitate that can plug an oil filter.
It simulates a problem that may be encountered in a new engine
run for a short period of time, followed by a long period of
storage with some water in the oil.
1.2 The values stated in SI units are to be regarded as
standard. No other units of measurement are included in this
standard.
1.3 This standard does not purport to address all of the
safety concerns, if any, associated with its use. It is the
responsibility of the user of this standard to establish appropriate
safety and health practices and determine the applicability
of regulatory limitations prior to use.