Plastics piping systems for water Supply and for buried and above-ground drainage and sewerage under pressure - Unplasticized poly(vinyl chloride) (PVC-U) - Part 4: Solvent cement
This Malaysian Standard specifies the requirements for solvent cement, supplied in cans or tubes for jointing unplasticised PVC pressure pipes complying with the requirements of MS 628:Part 1 and MS 762, unplasticised PVC fittings complying with the requirements of BS 4346:Part 1 and unplasticised PVC pipes and fittings complying with the requirements of BS 5481.
The solvent cement is also suitable, along with solvent cement complying with the requirements of BS 6209, for jointing products complying with the requirements of BS 4514, BS 4576:Part 1 and BS 4660.
NOTE. This Malaysian Standard does not specify the type of can used for solvent cement, but it recommends a colour for the cans.