High-pressure flexible connections for use with medical gas systems (First revision) (ISO 21969:2009, IDT)
This Malaysian Standard applies to high-pressure flexible connections intended to be connected to cylinders or cylinder bundles with nominal filling pressures up to 25 000 kPa at 15 °C for use with the following medical gases:
a) oxygen;
b) nitrous oxide;
c) air for breathing;
d) helium;
e) carbon dioxide;
f) xenon; mixtures of the gases listed above;
g) air for driving surgical tools;
h) nitrogen for driving surgical tools; and
i) oxygen-enriched air.
This standard applies to high-pressure flexible connections intended to connect cylinders or cylinder bundles to manifolds within sources of supply of medical gas pipeline systems complying with MS ISO 7396-1.
This standard applies to high-pressure flexible connections intended to connect a cylinder to an inlet port of medical equipment (e.g. anaesthetic workstation or lung ventilator) fitted with an integral pressure regulator complying with MS ISO 10524-1.
This standard does not apply to high-pressure flexible connectio
Published
• (none) / (none) / MS ISO 21969:2008
PDF
02/05/2019
21
NSC 18 - Medical Devices and Facilities for Healthcare