• :  
BM ENG
  • Home
  • Service
  • International Standard
  • FAQ
  • Publish
  • signin
  •  Cart ()

MS Preview

MS 589-3:2012
13 A plugs, socket-outlets, adaptors and connection units - Part 3: Specification for adaptors (Third revision)
This Malaysian Standard specifies requirements for adaptors having insulating sleeves on the line and neutral plug pins and suitable for use with socket-outlets complying with MS 589-2, with particular reference to safety in normal use. Adaptors specified in this standard are intended for household, commercial and light industrial purposes. The adaptors are suitable for the connection of portable appliances, sound-vision equipment, luminaires, etc., in a.c. circuits only, operating at voltages not exceeding 250 V r.m.s. at 50 Hz. This standard also applies to shaver adaptors which have the brass earth pin replaced with a similarly dimensioned protrusion made of insulating material designated as an insulated shutter opening device (ISOD) designed to operate the shutter mechanism of a socket-outlet conforming to MS 589-2. NOTE 1. Brass can be copper, phosphor-bronze or other metal at least equivalent with regard to its conductivity, resistance to abrasion, and resistance to corrosion. Assemblies comprising a plug and one or more portable socket-outlets connected together by a flexible cord or cable are not considered to be adaptors according to this standard. Devices incorporating switches, transformers, timers, thermostats or other control means are outside the scope of this standard. NOTES: 2. The titles of the publications referred to in this standard are listed on the inside back cover. 3. In order to maintain safety and interchangeability with plugs and socket-outlets it is necessary that these products comply with the requirements of Clause 9, Clause 12 and Clause 13, however their body outline need not be limited at a distance of 6.35 mm from the plug engagement surface. 4. Requirements for electromagnetic compatibility are not given for the following reasons. An adaptor does not emit intolerable electromagnetic interference since significant electromagnetic disturbances are only generated during insertion and withdrawal which are not continuous. An adaptor is mechanical by nature of construction. The product is therefore immune from electromagnetic interference.
Published
• (none)  / (none)  / (none)

PDF

10/07/2019
108
NSC 05 - Generation, Transmission & Distribution of Energy
29.120.30 
165.00

 Add To Cart
©2020 All rights reserved
Department of Standards Malaysia (STANDARDS MALAYSIA). Best viewed on latest browser.